MACSOC Assessment & Selection Training Facility


Subject: MACSOC Assessment & Selection Training Facility
Solicitation Number: W91236-21-B-2011
Notice Type: SOLICIT
NAICS: 236220
Set-Aside: Total Small Business
Notice Published: 05-03-21
Response Due: 05-17-21

Agency: Department of the Army
Office: W2SD ENDIST NORFOLK
Contact: Synease S McArthur This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (757) 201-7062
Office Address: NORFOLK, VA 23510-1096
Place of Performance: Fort A P Hill, VA 22427

Related Notices:
        03-30-21 SOLICIT

        04-08-21 SOLICIT

        04-20-21 SOLICIT

        03-02-21 SOLICIT

        03-10-21 SOLICIT

        04-06-21 SOLICIT

        05-11-21 SOLICIT

        05-11-21 SOLICIT

        02-25-21 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

4/28/2021 Amendment 0007 posted to provide responses to ProjNet inquiries. 4/20/2021 Amendment 0006 posted to extend the Bid Opening Submittal Due Date. 4/8/2021 Amendment 0005 posted to extend the Bid Opening Due Date. 4/6 the FFE packages has been removed and will be reuploaded at a later date. 4/5 Amendment 0004 posted to provide Ladder Specifications. 3/29/2021 Amendment 2 posted to provide SID and FF&E Attachments. This is the second Amendment for W91236-21-B-2011, and is listed as Amendment 0003. Amendment 0002 does not exist. 3/10/2021 Site Visit Sign In Sheet 3/2/2021 Amendment 1 posted to change the construction duration. 2/25 posted solicitation and drawings The MARSOC Assessment & Selection Training Facility a single story facility that consists of an approximately 7,134 Gross Square Foot (GSF) Pre-engineered Building structure with reinforced concrete foundation and floor slabs, slab on grade raised above 100 year flood plain, masonry veneer on 14 gauge cold formed metal studs. Roof shall be standing steam metal roof with a 2:12 slope secured directly to PEMB with cold formed metal roof purlins, HVAC high efficiency package located overhead interior of building supported by equipment platform, and automatic sprinkler protection. 130 personnel classroom high bay space separated from instructors and candidate quarters combined with utilities and 3 interview rooms. And, MARSOC Ops Building a single story facility that consists of an approximately 4,017 Gross Square Foot (GSF) one story Pre-engineered Building structure with reinforced concrete foundation and floor slabs, slab on grade raised above 100 year flood plain, masonry veneer on 14 gauge cold formed metal studs. Roof shall be standing steam metal roof with a 2:12 slope secured directly to PEMB with cold formed metal roof purlins, HVAC high efficiency package located overhead interior of building supported by equipment platform, and automatic sprinkler protection. 30 personnel workstations, two private offices in high bay space. Utilities, site improvements, landscaping, and other site and building related criteria are described in other chapters.