CONSTRUCTION OF DORMITORY AT JOINT BASE LANGLEY-EUSTIS, HAMPTON, VA


Subject: CONSTRUCTION OF DORMITORY AT JOINT BASE LANGLEY-EUSTIS, HAMPTON, VA
Solicitation Number: W9123626RA006
Notice Type: PRESOL
NAICS: 236220
Notice Published: 03-06-26
Response Due: 03-21-26

Agency: Department of the Army
Office: W2SD ENDIST NORFOLK
Contact: Jacob Coody This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (757) 201-7814
Office Address: NORFOLK, VA 23510-1096
Place of Performance: Joint Base Langley-Eustis Hampton, VA United States

Related Notices:
        03-06-26 PRESOL

        04-17-26 SOLICIT

        04-24-26 SOLICIT

        05-08-26 SOLICIT

        05-13-26 SOLICIT

        03-09-26 PRESOL

        03-30-26 SOLICIT

        06-05-26 SOLICIT

        05-05-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

Construct a dormitory with all necessary spaces to house 144 enlisted personnel at Joint Base Langley-Eustis. The construction includes 12 accessible rooms, compacted fill above the 100-year flood plain, reinforced concrete foundations and floor slabs, structural steel frame at building core and load bearing metal studs at building wings. The exterior walls are brick facade, precast concrete base, and limited metal panel walls and glass storefront in building core and entrances. The roof system is a structural steel frame with trusses at building wings and open web joists at building core and a standing seam metal roofing on building wings and low slope single-ply membrane roofing system on building central core. The project includes long-run outside plant communications and manhole/duct system pathway, connections to existing installation utility infrastructure, providing capacity to support facility loads. The project will include all necessary utilities, site preparation, pavements, site improvements, communication, remediation of petroleum contaminated soil within the footprint, security enhancements, area lighting, removal of utilities, and all necessary supporting work for a complete and usable facility. The facility must be able to withstand seismic and wind effects as prescribed in applicable codes and design guides. Facility will be designed as permanent construction in accordance with Department of Defense Unified Facilities Criteria 1-200-01 General Building Requirements. This project will comply with Department of Defense anti-terrorism/force protection requirements per Unified Facilities Criteria 4-010-01. Please see the attached Presolicitation Notice for additional information.