Project # 618-26-701 - EHRM - Infrastructure Upgrades - Main Computer Room Update - Minneapolis VAMC - Minneapolis, MN


Subject: Project # 618-26-701 - EHRM - Infrastructure Upgrades - Main Computer Room Update - Minneapolis VAMC - Minneapolis, MN
Solicitation Number: 36C77626B0017
Notice Type: PRESOL
NAICS: 236220
Set-Aside: Service-Disabled Veteran-Owned Small Business
Notice Published: 03-11-26
Response Due: 04-03-26

Agency: Department of Veterans Affairs
Office: VETERANS AFFAIRS, DEPARTMENT OF
Contact: Penhollow, Zachary E. This email address is being protected from spambots. You need JavaScript enabled to view it. Ph: (216) 447-8300
Office Address: INDEPENDENCE, OH 44131
Place of Performance: Minneapolis, MN 55417

Related Notices:
        05-12-26 SOLICIT

        04-21-26 SOLICIT

        05-07-26 SOLICIT

        05-26-26 SOLICIT

        06-23-26 SOLICIT

        06-09-26 SOLICIT

        07-01-26 SOLICIT

        05-26-26 SOLICIT

        08-25-26 AWARD

        07-15-26 SOLICIT


Click for official SAM (FBO) notice, additional information, and accompanying attachments

The Department of Veterans Affairs (VA), Veterans Health Administration (VHA), Program Contracting Activity Central (PCAC) anticipates soliciting bids and subsequently awarding a single firm-fixed-price contract for the design-bid-build to support the Electronic Health Record Modernization (EHRM) Infrastructure Upgrades construction project at the Minneapolis Veteran’s Affairs (VA) Medical Center (VAMC) located at One Veterans Drive, Minneapolis, MN 55417-2309. The Minneapolis VAMC is seeking a general contractor to consolidate and renovate all existing Data Center Spaces (2B-105 and BH-111) with no network downtime. This work includes but is not limited to: Lock out/Tag out of all sources of energy; Installation of new Information Technology (IT) equipment enclosures; New cold aisle containment with new rack power distribution units; New power distribution to the MCR and enclosures with new cable management; Structured cabling and management; Installing structure cabling in data center(s) and termination of existing campus fiber backbone; New redundant MDAs for A/B paths; Update data center layout and power distribution; Phased transfer of crucial power; Installation of UPS A/B; Provide additional raised floor shoring/structural supports; Provide temporary utilities; New core drills, installation or relocation of existing duct work and removal of unused legacy ductwork; Connect existing IT chilled water loop; and Renovation of requirements for the MCR within the specifications.